CR: Data grouping tardiness
Some CHARTrunner customers express the need to count or group data that has been accumulated during certain periods of time. Let’s pretend today is September 25, 2009 and consider the following...
SP: What is the maximum number of entries for a Choice List
Revision Date: 2005-09-12
You may have up to 199 choices per list. You can have as many choice lists as you need.
GN: Couldn't update; currently locked - error on Netware
Revision Date: 2005-12-13
Problem:
The following error was reported by a GAGEpack customer who had a GAGEpack database (which is a Microsoft Access database) on a Novell Netware shared drive:
...
SP: [SqcGroupDataSource.ValidateRecordset (31)] File sharing lock count exceeded. Increase MaxLocksPerFile registry.
...ecords, you get a message that reads: [SqcGroupDataSource.ValidateRecordset (31)] File sharing lock count exceeded. Increase MaxLocksPerFile registry."
Solution:
Upgrade to 4.5....
ST: Are there maximum values for Cp, Cpk, Pp and Ppk
Revision Date: 2005-09-06
No. As long as the spec range does not change and you continually reduce the variation, you will increase these indices. I have seen as high as 36 and ...
CR: A custom query for Length of Stay data
... as either a measurement (individuals chart) or a count (c-chart). The problem with this approach is... will not display. This is due to a subgroup size maximum of 100 for advanced row grouping.
Perha...
CR: Charting pass-fail data as a p-chart
...have Access 2000, here is the text of the query used to solve this problem:
TRANSFORM iif(IsNull(count([pfdata].PassFail)),0,count([pfdata].PassFail)) AS CountOfPassFail SELECT Min([pfdata].DATE) ...
How many metrics can I monitor with CHARTrunner-m?
...nterval (how often to check the data source for new data). Your CHARTrunner-m license specifies the maximum number of monitor definitions that you can concurrently have in the active state. For instan...
DP: What is the maximum for each of the following DOE types
Revision Date: 2005-09-01
The DOEpack limits are:
Full factorial - any combination if the number of runs < 32767
Fractional factorial - we provide tabled designs up ...
CR: Histogram bars beyond specification lines
...is bucket put each value that falls between 5.1 and 5.5. The size of each bar on the histogram is a count of the number of data values that were put into that particular bucket.
Next, imagine that ...
SP: Histogram bars beyond specification lines
...is bucket put each value that falls between 5.1 and 5.5. The size of each bar on the histogram is a count of the number of data values that were put into that particular bucket.
Next, imagine that ...
PS: Miutoyo's DT-10 Digimatic Data Transmitter and DL-10 Data Logger
...ted). The [13] is used as a CR or carriage return at the end of the string. The 0100 represents the maximum amount of data points being transmitted. You can increase or decrease this value based on th...
ST: 1 What is it
...s are the numerical values within which the system is expected to operate, that is, the minimum and maximum acceptable values. Occasionally there is only one limit, a maximum or minimum. Customers, en...
CR: Grouping counts by date in Excel
Revision Date: 2005-09-19
Problem:
Several customers have asked about counting by date. Imagine that you are collecting data where each row contains a date along with other information. You want t...
SP: Control over the number of decimal places on the X-axis of a histogram
...s, customize the parameters. If you enter custom parameters for the cells, the program will use the maximum number of digits in the 'cell start' and 'cell width' parameters to determin...
SP: Cannot enter all digits
...t enter, .3000 appears.
Solution:
Modify the group and change the identifers maximum length or update to version 4.0.106 or higher from the Maintenance Release page. Follow the ...
CR: Excel tips
... do not contain a month – they contain something different. The same can be said for the Item count and error count columns.
If the primary purpose of this sheet is to “enter data for mo...
ST: Stability and linearity - Keys to an effective measurement system
...ipment not calibrated at the upper and lower end of the operating range;
Error in the minimum or maximum master;
Worn equipment;
Possible review of internal equipment design characters.
Pro...
ST: Sampling and Data Collection
Revision Date: 2005-09-06
Assume you are managing a process making 100+ parts per hour for one of your customers. This customer requires that you control your process and...
ST: Gentlemen, start your gages - R&R and variability
Revision Date: 2005-09-06
by Gordon Constable
A number of factors affect the ability of a measurement system to discriminate among the units it measures. These factors can ...