  1. CR: Background on out-of-control test rulesCR: Background on out-of-control test rules
    Revision Date: 2005-09-19 This article applies to CHARTrunner versions 1.7 and above. CHARTrunner does out-of-control testing on all control charts. This testing is based upon rules called out-o...
  2. CR: Charting pass-fail data as a p-chartCR: Charting pass-fail data as a p-chart
    Revision Date: 2005-09-19 Problem: Several customers have asked questions about making a p-chart from data in this general form: SerialNumber Date PassFail ...
  3. CR: Multiple chart lines from one data columnCR: Multiple chart lines from one data column
    Revision Date: 2005-09-19 Problem: You may have a need to look at a single data column and create a chart with more than one data line. Imagine a spreadsheet containing many ro...
  4. CR: Bar Chart of a column of numbers in various categoriesCR: Bar Chart of a column of numbers in various categories
    Revision Date: 2007-03-29 Problem: You have a large column of numeric values in an Excel spreadsheet. You would like to see a bar chart showing how many numbers fall into some predefined catego...
  5. GP: Maintenance events grayed outGP: Maintenance events grayed out
    Revision Date: 2005-08-10 Problem: After converting to GAGEpack 6.5 with user login turned on, none of the users including the SUPERVISOR have the Maintenance option. Solution: Maintenance was ...
  6. CR: Charting from IndustrialSQL ServerCR: Charting from IndustrialSQL Server
    Problem: You need to setup a CHARTrunner chart definition to chart data from tags that reside in Wonderware's IndustrialSQL Server. IndustrialSQL Server is a real-time relation...
  7. CR: Using a Password Protected Microsoft Access DatabaseCR: Using a Password Protected Microsoft Access Database
    Problem: Ref #757, Last Revision 02-14-2003. A Microsoft Access database can be password protected using one of the following methods: · Database Password – A password is applied t...
  8. CR: Using a Text File as a Data SourceCR: Using a Text File as a Data Source
    Problem: When you specify a text file as the CHARTrunner data source, the data from the text file will not be read correctly if the format of the text file is “nonstandard”. In CHA...
  9. CR: X-axis labels, causes, notes, & vertical grid linesCR: X-axis labels, causes, notes, & vertical grid lines
    Revision Date: 2005-09-01 Problem: X-axis labels, causes, notes, and vertical grid lines do not appear on the chart. Solution: If a variables or attributes control chart con...
  10. GP: When I exit GAGEpack, I am using one filter, but when I restart the software, another filter loads. Why?GP: When I exit GAGEpack, I am using one filter, but when I restart the software, another filter loads. Why?
    Revision Date: 2005-09-02 Problem: If you exit GAGEpack with one filter on your gage list and then you return to a new filter for the gage list, it is possible that someone has a startup filter in...
  11. PS: Mitutoyo Input Tool Model 264-007, IT-007RPS: Mitutoyo Input Tool Model 264-007, IT-007R
    ... Date: 2005-09-19 Baud rate = 2400 Data bits = 8 Stop bits = 1 Parity = None Control = None RTS = N/A Ref # 497
  12. PS: Miutoyo's DT-10 Digimatic Data Transmitter and DL-10 Data LoggerPS: Miutoyo's DT-10 Digimatic Data Transmitter and DL-10 Data Logger
    ...005-09-19 Baud rate = 1200 or 2400 Data bits = 8 Stop bits = 1 Parity = None Control = None RTS = Enable Initialization String (IS)= S1A0100[13] Request String (RS)...
  13. PS: MUX-10PS: MUX-10
    ...1200 (dip switch #3 ON/down, #4OFF/up) Data bits = 7 Stop bits = 1 Parity = Space Control = None RTS = Enabled Comments: If no data comes across, make sure that the cable from the MUX-10...
  14. PS: Smart CablePS: Smart Cable
    ...ion Date: 2005-09-19 Baud rate = 9600 Data bits = 8 Stop bits = 1 Parity = None Control = None RTS = Enabled Comments: Host Command/Request string= R1[13] Ref # 481
  15. PS: Starrett micrometerPS: Starrett micrometer
    ...ion Date: 2005-09-19 Baud rate = 1200 Data bits = 7 Stop bits = 2 Parity = None Control = XON/XOFF RTS = Enabled Comments: There is a difference between these settings a...
  16. PS: Starrett micrometer 721BPS: Starrett micrometer 721B
    ... Baud rate = 4800 Data bits = 7 Stop bits = 1 Parity = Space Control = None RTS = Enabled Ref # 504