PQ Systems Knowledge Base

View Articles by Category

There are no sub categories

Category » Error Messagesrss button

There were 9 articles found in this category:

  1. questionGP: Gagepack will not install
    Revision Date: 2005-09-02 Problem: A customer was having a problem installing GAGEpack 2000 5.0. It would go through about 4% of the install and then abort saying \"component transfer error GAGEpack 2000 files Program Files System cannot find the path specified.\" Solution: Look for this fo ...
  2. questionGP: Reports are Hidden
    Revision Date: 2005-09-02 Problem: Reports are "Hidden" - they appear to generate, but nothing gets displayed. Solution: Select "Tile Horizontally" on the Windows Task Bar and the report is now visible. Ref# 900
  3. questionGP: Unable to connect to data
    Revision Date: 2005-09-02 Problem: When I try to print my reports, I get the message \"unable to connect to data server.\" What should I do now? Solution: You will receive this error message when the OLE server that GAGEpack uses for reporting has not been registered correctly in your Windows\\ ...
  4. questionGP: Field Gages.RRFileName cannot be a zero-length string
    Revision Date: 2005-09-02 Problem: When a new gage is added the following message appears: Field ‘Gages.RRFileName’ cannot be a zero-length string. If I enter something in this RRFileName field, I then get another similar error for several other fields: Field ‘Gages.Group’ cannot be a zero-leng ...
  5. questionGP: Oleaut32.dll is out of date
    Revision Date: 2005-09-02 Problem: "Oleaut32.dll is out of date" appears during installation of GAGEpack 2000. Solution: On a Windows 95 or 98 PC: Reinstall GAGEpack 2000 in safe mode. In safe mode, you will not be able to access your CD drive, so you should copy necessary files first. 1. Cop ...
  6. questionGP: Unrecognized database format
    Revision Date: 2005-09-02 Problem: "Unrecognized database format" errors in GAGEpack caused by opening & converting a GAGEpack database in Access. Solution: GAGEpack 5.0 stores data in an Access 97 database format. It is possible to open the GAGEpack database in Access 2000. If you answered ...
  7. questionGP: Unable to register OLEAUT32.dll
    Revision Date: 2005-09-02 Problem: "Unable to register OLEAUT32.dll" appears while you are installing GAGEpack 2000 on a Windows NT workstation. Solution: Contact your systems administrator to determine if profiles are being applied. If profiles are being applied, then have the administrator lo ...
  8. questionGP: Invalid use of null
    Revision Date: 2005-09-02 Problem: "Invalid use of null" appears as you are trying to Calibrate a gage. Solution: Contact PQ Technical Support with the Reference number 562 to correct the problem. In North and South America, contact our US office at: 800-777-5060 or 937-885-2255 or support@pqs ...
  9. questionGP: [Start.Main (73)]
    Revision Date: 2005-09-02 Problem: When starting, [Start.Main (73)] Out of Memory error occurs. The error occurred when trying to bring up the information screen for First Time users. Solution: Edit GPwin50.INI in the \GAGEpack 2000 5.0 folder We added: FirstTime=0 below the line for GAGEpackPr ...